ZPE_Logo
  
Search        
  Create an account Home  ·  Topics  ·  Downloads  ·  Your Account  ·  Submit News  ·  Top 10  
Mission Statement

Modules
· Home
· Forum
· LATEST COMMENTS
· Special Sections
· SUPPORT ZPEnergy
· Advertising
· AvantGo
· Books
· Downloads
· Events
· Feedback
· Link to us
· Private Messages
· Search
· Stories Archive
· Submit News
· Surveys
· Top 10
· Topics
· Web Links
· Your Account

Who's Online
There are currently, 816 guest(s) and 0 member(s) that are online.

You are Anonymous user. You can register for free by clicking here

Events
  • (June 24, 2026 - June 28, 2026) 2026 ESTC CONFERENCE

  • Hot Links
    Aetherometry

    American Antigravity

    Closeminded Science

    EarthTech

    ECW E-Cat World

    Innoplaza

    Integrity Research Institute

    New Energy Movement

    New Energy Times

    Panacea-BOCAF

    RexResearch

    Science Hobbyist

    T. Bearden Mirror Site

    USPTO

    Want to Know

    Other Info-Sources
    NE News Sites
    AER_Network
    E-Cat World
    NexusNewsfeed ZPE
    NE Discussion Groups
    Energetic Forum
    EMediaPress
    Energy Science Forum
    Free_Energy FB Group
    The KeelyNet Blog
    OverUnity Research
    Sarfatti_Physics
    Tesla Science Foundation (FB)
    Vortex (old Interact)
    Magazine Sites
    Electrifying Times (FB)
    ExtraOrdinary Technology
    IE Magazine
    New Energy Times

    Interesting Links

    Click Here for the DISCLOSURE PROJECT
    SciTech Daily Review
    NEXUS Magazine

    Tilley generator tests
    Posted on Thursday, August 12, 2004 @ 22:09:39 UTC by vlad

    Devices Jerry Decker writes (KeelyNet.com): Hola Folks!

    Norman Bollinger gave me the headsup on this page, for what its worth. How many years is this going to go on, with claims and such but never a machine or product to buy, test or USE? What is the point?

    Note it says 'certified test results', now who would that BE that certified those results? Why isn't that information included?

    Geez, I wanna believe but this last little DIDO with the electric bikes due to for SALE in July that didn't happen was just the last straw for me.

    However, here are the 'certified test results'...now where can we buy one??????????????????????? If not, WHY NOT???

    http://www.tilleyfoundation.com/gen.htm


    Test Results of the Tilley All Electric Generator

    Below are certified test results for the Tilley Generator . This is
    almost the same type of system that was originally set up at the Tilley
    Foundation complex to power the shop building (1,800 square foot
    building) with the exception of less batteries.

    Test: Several areas are to be tested to insure certification. Each of
    the below test were conducted one after the other with stoppage only the
    check battery voltage and then turned back on for next test.

    (1) Check battery voltage prior to commencing test

    RESULTS: " Battery voltage at start of test read 12.8 VDC"

    (2) Turn on Generator and allow running for five minutes with no load.
    At the end of the 5 minute run check battery voltage to verify that
    generator could work on it's on with no load and maintain battery
    status.

    RESULTS: "After the five minute run Battery Voltage test

    Verified at 12.9 VDC."

    (3) Turn Generator on and apply a load to run for 10 minutes. Test
    Battery voltage after run to verify battery voltage. Power tool selected
    was an 11 amp (1,320 watt)

    Skilsaw 7 1/4 model number 5150

    RESULTS: "After the ten minute run Battery Voltage test

    Verified at 12.9 VDC."


    (4) Turn Generator on and apply a load and run for 15 minutes. Test
    Battery after run to verify battery Voltage. Item selected was a 75 watt
    drop light.

    RESULTS: "After 15 minute run Battery Voltage test

    Verified at 12.9 VDC."



    (5) Turn Generator on to test a load under heavy shop and construction
    site conditions. Run the generator utilizing power tools for a period of
    30 minutes (1/2 hour) continuous.

    Items to be Tested and verified are:

    11 amp skilsaw, 3.5 amp drill 6.8 amp Band saw, 3.5 amp

    grinder, 3.5 amp jigsaw, 12.5 amp compressor and a 75

    watt Light. (Over 4,700 watts )

    Some items will be turned on at the same time and will be used to cut
    wood, drill holes and grind metal as under normal power tool use.

    At conclusion of the test Battery Voltage will be verified.

    RESULTS: " After 30 minute (1/2 hour) run Battery Voltage test

    Verified at 12.8 VDC."

    (6) Turn Generator on to test expanded run for one (1) hour utilizing
    basic household items running at the same time. Items to be tested and
    verified are:

    TV, VCR, two (2) 60 watt lights, electric razor, make some popcorn in a
    microwave oven, make pot of coffee with a drip coffee maker. (Over 2,465
    Watts total)

    At conclusion of the one hour test battery voltage will be verified.

    RESULTS: "After one (1) hour run Battery Voltage test Verified at 12.8
    VDC."


    (7) Turn Generator on to test two (2) hour run with one (1) 60 watt
    light and plug in additional items every 40 minutes.

    Items to be tested and verified are:

    60 watt light, jig saw, power drill and computer. (1,425 watts )

    At conclusion of the two (2) hour test battery voltage will be verified.

    RESULTS: "After two (2) hour run Battery Voltage test Verified at 12.8
    VDC."

    (8) Turn generator on. Run 4 (four) hour long test. Install a load
    consisting of five (5) 60 watt lights (300 watts total).

    At conclusion of the 4 (four) hour run battery voltage will be verified.

    RESULTS: "After four (4) hour run Battery Voltage test verified at
    12.8 VDC

    CONCLUSION: Test results of an 8 (eight) hour continuous test run
    reveled that the Tilley Commercial Generator maintained full state of
    charge under various load conditions.

    Power draw from the charging device drive motor was not factored into
    the power usage as the charger maintained battery voltage despite the
    load.

    There was no heating problem and the inverter maintained the surge power
    of all items used.

    If the item was to be used as a total house package a larger inverter
    system would be required.

    In a standard shop or construction site use as a generator with all 120
    AC items it would achieve its objective.

    a No fuel of any sort was used.

    a No outside power from the utility grid was used.

    a No solar, wind turbine or water power was used.

    a No fuel cell was used.

    a The test was conducted with the Tilley Commercial Generator only.

    a Only two off the shelf 12 VDC batteries were used.

    a One Trace DC to AC 3,500 watt inverter with 5,000 watt surge was used.

    a Total size is 36 inches long..24 inches high..17 inches wide

    a Total weight 154 pounds

    ---
    Jerry Decker / http://www.keelynet.com
    From an Art to a Science
    Archive http://www.escribe.com/science/keelynet


     
    Login
    Nickname

    Password

    Security Code: Security Code
    Type Security Code

    Don't have an account yet? You can create one. As a registered user you have some advantages like theme manager, comments configuration and post comments with your name.

    Related Links
    · More about Devices
    · News by vlad


    Most read story about Devices:
    Overunity magnet motor released !


    Article Rating
    Average Score: 3.66
    Votes: 3


    Please take a second and vote for this article:

    Excellent
    Very Good
    Good
    Regular
    Bad


    Options

     Printer Friendly Printer Friendly


    "Tilley generator tests" | Login/Create an Account | 0 comments
    The comments are owned by the poster. We aren't responsible for their content.

    No Comments Allowed for Anonymous, please register

     

    All logos and trademarks in this site are property of their respective owner. The comments are property of their posters, all the rest © 2002-2016 by ZPEnergy. Disclaimer: No content, on or affiliated with ZPEnergy should be construed as or relied upon as investment advice. While every effort is made to ensure that the information contained on ZPEnergy is correct, the operators of ZPEnergy make no warranties as to its accuracy. In all respects visitors should seek independent verification and investment advice.
    Keywords: ZPE, ZPF, Zero Point Energy, Zero Point Fluctuations, ZPEnergy, New Energy Technology, Small Scale Implementation, Energy Storage Technology, Space-Energy, Space Energy, Natural Potential, Investors, Investing, Vacuum Energy, Electromagnetic, Over Unity, Overunity, Over-Unity, Free Energy, Free-Energy, Ether, Aether, Cold Fusion, Cold-Fusion, Fuel Cell, Quantum Mechanics, Van der Waals, Casimir, Advanced Physics, Vibrations, Advanced Energy Conversion, Rotational Magnetics, Vortex Mechanics, Rotational Electromagnetics, Earth Electromagnetics, Gyroscopes, Gyroscopic Effects

    PHP-Nuke Copyright © 2005 by Francisco Burzi. This is free software, and you may redistribute it under the GPL. PHP-Nuke comes with absolutely no warranty, for details, see the license.